High Precision Split Core Current Transformer

High Precision Split Core Current Transformer

Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard .
Chat Now

Product Details

Description
Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard . 

Application
•   Data logging        •   Recording   •   Power monitoring
•   Energy management  •   Alternative energy monitoring
•   Cost allocation

Features
• High accuracy at 10-130% of rated current
• AC isolation resistance: 3KV for 60s
• Swing open for ease of installation 
• Double secured latches per side and keying holes
• Rigid housing case with UL® 94V-0 durable plastic
• Safety standard: IEC/EN60044-1
• Nominal phase angle error and
Nominal linearity error: Conform IEC61869-2
                    ConformIEC60044-1
•Max.operation voltage:  AC600V

Specificaiton

Item

                                                                                          Specificaiton

Inputs


Frequency range                                                                                              

50-60Hz

Accuracy range                                                                                 

 10-130% of rated current

Outputs


output at rated current                                                                              

  2mA-200mA 

Enviromental


Operaiton temperature range                                               

-10°C to +60°C (+14°F to +140°F)

Storage temperature range                                                     

 -20°C to +85°C (+4°F to +185°F)

Lead length                                                                        

70 ft black/white twisted pair wire leads-22 AWG

Certifications                                                                                                      

RoHS

Mechanical Specificaitons:

High-Precision-Split-Core-Current-Transformer-1-1000.webp (2)


Part Number


Description


A


B


C


D


E

 
ΦF

Primary Rated
Ampers

  Weight

g

LO-SP3010

CT 1:3000,  0.5% accuracy

40.5

24.6

22

26

14.5

10

5, 15, 30, 50, 75,80


LO-SP3016

CT 1:3000,  0.5% accuracy

44

27

29

31

19

16

50, 70, 100, 120


LO-SP3024

CT 1:3000,  0.5% accuracy

75

46

45

35

19.5

24

100, 150, 200, 300


LO-SP3036

CT 1:3000,  0.5% accuracy

91.6

58

57.4

40.9

22.8

36

300, 400, 500, 600