Three Phase Balance Protection Usage Zero Phase Current Transformer

Three Phase Balance Protection Usage Zero Phase Current Transformer

The current transformer is divided into a current transformer for measurement and a current transformer for protection; the function of the current transformer for measurement is used to measure (charge) and measure the current of the operating device
Chat Now

Product Details

We pursue the administration tenet of 'Quality is exceptional, Assistance is supreme, Reputation is first', and will sincerely create and share success with all clients for 200A: 5A Center Through Current Transformer, Split Core Current Transformer, Digital Window Current Transformer. Passion is the source of our forward attitude and strength. We are based on honesty, seek development on the basis of credibility, wholeheartedly serve the new and old customers, and work with you to create brilliant. Welcome all the clients old and new to visit our company and talk about the business. We develop the market with quality and win support with integrity.

Introduction

The current transformer is divided into a current transformer for measurement and a current transformer for protection; the function of the current transformer for measurement is used to measure (charge) and measure the current of the operating device; the current transformer for protection mainly and the relay device Cooperate, when the line is short-circuit overload and other faults, provide a signal to the relay device to cut off the fault circuit to protect the safety of the power supply system.


Precision Current Transformer(001)


Absolute Maximum Ratings


Operating free air temperature range

-40ºC to 85ºC

Storage temperature range

-40ºC to 100ºC

Leads Information

24AWG UL1007 Lead wires

Leads length:105±5mm

Stripped and tinned

4±2mm

Advantages

1. High and low voltage completely isolated, high safety, excellent insulation performance, no iron core, eliminating magnetic saturation and ferromagnetic resonance.

2. Good anti-electromagnetic interference performance, no open circuit high voltage danger on the low voltage side.

3. Large dynamic range, high measurement accuracy and wide frequency response range.

4. Data transmission anti-interference ability.

5. Small size and light weight.

Precautions

1. When the current transformer is verified, the current ratio of the standard current transformer to the current transformer to be tested must be the same.

2. Strictly follow the wiring shown in the figure.

3. Before testing the transformer, you must first test whether the load box is accurate.

4. During the verification process, it is forbidden to open the secondary winding.

5. Demagnetize before the transformer is verified. The demagnetization line is shown in Figure 4.

6. Open the circuit twice, adjust the regulator evenly and slowly, so that the indication of the dial indicator increases from 0 to 100%, and then evenly and slowly drops to zero. Repeat this process 2 to 3 times. The secondary winding should be shorted before the power is turned off after the demagnetization is completed.

7. The wiring schematic diagram of the current transformer with current riser is basically the same as the above wiring diagram, except that the output winding of the current riser and the primary winding of the transformer are the same winding, and the rest are the same.

QQ图片20200716135417_meitu_1

We know that we only thrive if we could guarantee our combined price tag competiveness and quality advantageous at the same time for Three Phase Balance Protection Usage Zero Phase Current Transformer. We hope to improve the innovation mechanism and organizational structure through continuing to strengthen the sustainable development path, and integrating internal and external resources from a strategic height. We should cooperate with other companies to complement each other's advantages in order to strengthen our competitiveness together, and therefore adapt to the competitive environment of the contemporary market.