Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposing CT

Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposing CT

The CT series current transformers are plug-in primary types with a secondary loop wound around a directional electrical steel core.It is often referred to as a meter transformer for measuring current.
Chat Now

Product Details

With the fierce market competition and customer demand for new products, it is necessary for us to further develop new Current Transformer PCB CT factory, Automatic Disposable Protective Face Masks Machine, Center Through Current Transformer. Anytime anywhere we are still here to be your partner. We continue to develop new products to meet the market demand, improve the product grade, and use advanced testing equipment. The reason why we can provide such a wide range of products stems from our commitment to meet customer needs and continuous improvement.

Introduction

The CT series current transformers are plug-in primary types with a secondary loop wound around a directional electrical steel core.It is often referred to as a meter transformer for measuring current. The current transformer produces a reduced current that is precisely proportional to the current in the circuit and can be easily connected to the measuring and recording instrument.


CT Series Current Transformers(001)


Application

Our products can sense overload current, ground fault detection, and current signal measurement.

Function

The current transformer is divided into a current transformer for measurement and a current transformer for protection; the function of the current transformer for measurement is used to measure (charge) and measure the current of the operating device; the current transformer for protection mainly and the relay device Cooperate, when the line is short-circuit overload and other faults, provide a signal to the relay device to cut off the fault circuit to protect the safety of the power supply system.

The causes and solutions of the following six faults in current transformers

1. When it is found that the current transformer has a secondary open circuit, it is necessary to distinguish the occurrence point of the fault, and the different phases of the switch, which will affect the entire protection, and report and schedule the situation, which may occur. The situation of misoperation is directly lifted;

2.It is best to reduce the load current once as much as possible. If the damage of the current transformer is serious, the load should be transferred and directly powered off for processing and inspection;

3.On the nearest test terminal, the current transformer is subjected to a secondary short circuit, and then the open circuit point is checked, and a relatively short wiring is used;

4. If there is a spark in the process of short circuit, it means that the short circuit is effective, and also indicates that the fault point is in the circuit of the short contact point;

5. Conversely, if there is no spark in the short circuit process, it means that the short circuit has no effect, and the fault point should not be in the loop;

6. Transfer the secondary short-circuit operation of the current transformer. It is best to perform power failure and check. When the current transformer is in secondary switch, it must use insulated tools with good insulation effect. Related tools such as gloves.

123456

QQ图片20200716135417_meitu_1

New Delivery for Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposing CT. At our firm with quality first as our motto, we manufacture products that are entirely made with high quality, from materials procurement to processing. We advocate the research and application of modern marketing and grow with our customers in guiding and better meeting customer needs.

Inquiry

You Might Also Like