Ce and RoHS Approval Split Core Current Transformer

Ce and RoHS Approval Split Core Current Transformer

Our product have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.
Chat Now

Product Details

In the production process, we formulate strict technical procedures and testing requirements to ensure the quality of the High Precision Split Core Current Transducer, Residual Current Detection Current Transformer, Zero Sequence Current Transformer Cores. According to the needs of every customer, we give customized & personalised services to help customers achieve their goals successfully. Maintaining good physical and mental health in work and daily life of every employee will lay a solid foundation for our long-term development. Our stock have valued 8 million dollar, you can find the competitive parts within short delivery time.

Description

Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard .

Application

• Data logging • Recording • Power monitoring

• Energy management • Alternative energy monitoring

• Cost allocation

Features

• High accuracy at 10–130% of rated current

• AC isolation resistance: 3KV for 60s

• Swing open for ease of installation 

• Double secured latches per side and keying holes

• Rigid housing case with UL® 94V-0 durable plastic

• Safety standard: IEC/EN60044-1

• Nominal phase angle error and 

Nominal linearity error: Conform IEC61869-2

 ConformIEC60044-1

•Max.operation voltage: AC600V

Specification

Item

Specification

Inputs

Frequency range 50-60Hz

Accuracy range 10-130% of rated current

Outputs

output at rated current  2mA-200mA

Environmental

Operation temperature range -10°C to +60°C (+14°F to +140°F)

Storage temperature range-20°C to +85°C (+4°F to +185°F)

Lead length70 ft black/white twisted pair wire leads-22 AWG

CertificationsRoHS


Mechanical Specification

图片1


 Part Number

 Description

 A

 B

 C

 D

 E

 ΦF

PrimaryRated Amper

Weight
(g)

LO-SP3010

CT1:3000,  0.5% accuracy

40.5

24.6

22

26

14.5

10

5, 15, 30,50, 75,80


LO-SP3016

CT1:3000,  0.5% accuracy

44

27

29

31

19

16

50, 70, 100,120


LO-SP3024

CT1:3000,  0.5% accuracy

75

46

45

35

19.5

24

100, 150,200, 300


LO-SP3036

CT 1:3000, 0.5% accuracy

91.6

58

57.4

40.9

22.8

36

300, 400,500, 600



Installation

图片2

Our service

1.Provide the technical design and solutions;

2.Designing and manufacturing of non-standard products;

3.We can guarantee on-time delivery of samples and goods.

4.Supply accessories at any time;

5.Technical consulting and services;

6.Other special technical service according to client’s requirements.

QQ图片20200716135417_meitu_1

Our corporation has a excellent assurance program are actually established for Ce and RoHS Approval Split Core Current Transformer. Our pursuit is the corporate culture with ethics and humanity as its core values. Each after-sales service personnel have many years of experience to ensure that they can solve problems quickly and accurately for customers.