600A 0.5 Class Busbar Type Split Core Window Current Transformer Single Phase CT

600A 0.5 Class Busbar Type Split Core Window Current Transformer Single Phase CT

Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.
Chat Now

Product Details

This company constantly surpasses itself, improves itself, and strives to become the leader in the Current Sensor Transformerhigh Precision CT, Rectange Split Core Current Sensor factory, Single Phase Current Transformer industry. We have cultivated and created a young, highly educated, proficient organization team with a sense of positive innovation. We are a product and technology provider with service concept as the core. Our company is an enterprise platform to realize the life value of every lookout person and also an enterprise that achieves the dream of team by achieving the individual dream of each employee.

Introduction

Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.

Features

• High accuracy at 10-130% of rated current

• AC isolation resistance: 3KV for 60s

• Swing open for ease of installation

• Double secured latches per side and keying holes

• Rigid housing case with UL® 94V-0 durable plastic

• Safety standard: IEC/EN60044-1

• Nominal phase angle error and

Nominal linearity error: Conform IEC61869-2

ConformIEC60044-1

•Max.operation voltage: AC600V

Specificaiton

Item

Specificaiton

Inputs


Frequency range 50-60Hz

Accuracy range 10-130% of rated current

Outputs

output at rated current 2mA-200mA

Enviromental

Operaiton temperature range -10°C to +60°C (+14°F to +140°F)

Storage temperature range -20°C to +85°C (+4°F to +185°F)

Lead length 70 ft black/white twisted pair wire leads-22 AWG

Certifications RoHS

Mechanical Specificaitons

image001

Part Number

Description

A

B

C

D

E

ΦF

Primary Rated
Ampers

Weight

g

LO-SP3010

CT 1:3000, 0.5% accuracy

40.5

24.6

22

26

14.5

10

5, 15, 30, 50, 75,80


LO-SP3016

CT 1:3000, 0.5% accuracy

44

27

29

31

19

16

50, 70, 100, 120


LO-SP3024

CT 1:3000, 0.5% accuracy

75

46

45

35

19.5

24

100, 150, 200, 300


LO-SP3036

CT 1:3000, 0.5% accuracy

91.6

58

57.4

40.9

22.8

36

300, 400, 500, 600


Installation

image003

Application

● Data logging

● Recording

● Power monitoring

● Energy management

● Alternative energy monitoring
● Cost allocation

QQ图片20200716135417_meitu_1

We will devote ourselves to giving our esteemed buyers using the most enthusiastically thoughtful services for 600A 0.5 Class Busbar Type Split Core Window Current Transformer Single Phase CT. Our company's production line has been further expanded in recent years. We have a wide range of products, sincerely welcome your patronage and cooperation. The mission of our company is to provide the highest quality products with best price.

Inquiry

You Might Also Like