20 (100) a Single Phase DIN Rail Energy Meter with One Split Core CT for Renovation Projects

20 (100) a Single Phase DIN Rail Energy Meter with One Split Core CT for Renovation Projects

Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.
Chat Now

Product Details

Our company sells a complete range of 200A: 5A Center Through CT, Mini Split-core AC Current Transformer, Ferrite Rod Core Coil, which can meet the needs of different customer groups. Through standardized process operation mode and strict product inspection, we provide customers with timely, stable and efficient logistics services. We fully rely on technological development to be invincible in the fierce competition with outstanding quality and exquisite appearance. Now our company has formed a new strategy integrating new product promotion, production, sales and service, adhering to the concept of 'integrity-based, customer first'.

Introduction

Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.

Features

• High accuracy at 10-130% of rated current

• AC isolation resistance: 3KV for 60s

• Swing open for ease of installation

• Double secured latches per side and keying holes

• Rigid housing case with UL® 94V-0 durable plastic

• Safety standard: IEC/EN60044-1

• Nominal phase angle error and

Nominal linearity error: Conform IEC61869-2

ConformIEC60044-1

•Max.operation voltage: AC600V

Specificaiton

Item

Specificaiton

Inputs


Frequency range 50-60Hz

Accuracy range 10-130% of rated current

Outputs

output at rated current 2mA-200mA

Enviromental

Operaiton temperature range -10°C to +60°C (+14°F to +140°F)

Storage temperature range -20°C to +85°C (+4°F to +185°F)

Lead length 70 ft black/white twisted pair wire leads-22 AWG

Certifications RoHS

Mechanical Specificaitons

image001

Part Number

Description

A

B

C

D

E

ΦF

Primary Rated
Ampers

Weight

g

LO-SP3010

CT 1:3000, 0.5% accuracy

40.5

24.6

22

26

14.5

10

5, 15, 30, 50, 75,80


LO-SP3016

CT 1:3000, 0.5% accuracy

44

27

29

31

19

16

50, 70, 100, 120


LO-SP3024

CT 1:3000, 0.5% accuracy

75

46

45

35

19.5

24

100, 150, 200, 300


LO-SP3036

CT 1:3000, 0.5% accuracy

91.6

58

57.4

40.9

22.8

36

300, 400, 500, 600


Installation

image003

Application

● Data logging

● Recording

● Power monitoring

● Energy management

● Alternative energy monitoring
● Cost allocation

QQ图片20200716135417_meitu_1

Each of our 20 (100) a Single Phase DIN Rail Energy Meter with One Split Core CT for Renovation Projects is made of high-quality raw materials, which is the bearing of experience and creativity. It is hoped that we can gradually move towards diversification and group management in the industry and maximize the benefits of scale through the possession of the domestic market and the export of technology and products in the international market. We have our own factory and sourcing office.

Inquiry

You Might Also Like