Introduction:

In the electrical systems always exists the possibility of having shutdowns due to over currents or short circuits produced by operation mistakes, ambient conditions, lack of maintenance or atmospheric  discharges. Ground fault it occurs when one of the system phases get on direct contact to ground or to any metallic part that is grounded. The ground fault has its origin on different ways but the more common are reduced insulation, physical damages to insulation system or excessive transient or steady-state voltage stresses on insulation.  These problems can be produced due to moisture, atmospheric contamination, insulation deterioration, mechanical stresses, etc. Although the situations mentioned before can be avoided following a good maintenance Schedule, always exists the latent risk of a fault, commonly during the installation or major maintenance to equipment.

Mechanical Specificaitons

Residual-Current-Transformer-Current-up-to-100A.webp (1)

P/N

Main circuit Current
(A)

Diameter(Φ)
(mm)

Dimensions(mm)

Layout dimensions(mm)

L

W

H

D1-D2

M

LO-ZCT513102

0-100A

46

85

32

92.5

88-100

6

LO-ZCT513202

0-250A

65

108

32

118.5

109-122.5

6

LO-ZCT513302

0-315A

80

128

36

138.5

134-144

6

LO-ZCT513402

0-630A

100

150

36

160.5

152-171.5

6

LO-ZCT513502

0-800A

120

172

36

182.5

177-196.5

6

ABSOLUTE MAXIMUM RATINGS

Operating free air temperature range

-20ºC to 65ºC

Storage temperature range

-40ºC to 85ºC

Residual-Current-Transformer-Current-up-to-100A.webp (3)Residual-Current-Transformer-Current-up-to-100A.webp (4)Residual-Current-Transformer-Current-up-to-100A.webp (5)

High accuracy qualified:
This series of products are on the basis of the existing mature technology, choose more high quality raw materials and combined with the optimization of the shape design, test accuracy gets strong guarantee and better than the national standard requirements: 0.5%, for special requirements,  accuracy can reach to 0.2%.

     This project combines the optimal magnetic circuit design, and take full account of the necessary space requirements, so as to ensure the balance test. If necessary, the balance property can be in the specified detection conditions to achieve 5mA-50mA. Fully meet the detection circuit requirements.

     At the same time, this series of products can be used for main circuit current testing, and fire power monitoring current, detection current scope from 50A-2000A, Accuracy is better than class 0.5 when secondary output at 5A .Accuracy is better than class 0.2S level when secondary output at 1A,

When measure high current , mA level weak signal can be outputed,the accuracy is better than class 0.1


Shipping:
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country.

QQ图片20200716135417_meitu_1


Inquiry

You Might Also Like