Introduction
A new type of current sensor based on the principle of magnetic modulation is developed,which can measure the small DC current signal in mA level under the condition of electrical isolation.
Electrical Parameters | ||||||
P/N | LO-DS010LT | LO-DS020LT | LO-DS050LT | LO-DS100LT | ||
IPN | Rated input current | 10 | 20 | 50 | 100 | mA |
IP | Measuring current range | 0~±12 | 0~±240 | 0~±60 | 0~±120 | mA |
VOUT | Rated output voltage | 5±1% | V | |||
VC | Power voltage | ±12~±15(±5%) | V | |||
IC | Current loss | VC=±15V <30 | mA | |||
Vd | Hi-pot test | P-S:AC3KV/50Hz/60S | ||||
εL | Linearity | <±1 | %FS | |||
V0 | Zero point offset voltage | TA=25℃ ±50 | mV | |||
VOT | Temperature drift of malfunction | IP=0 TA=10~+70℃ <±1 | mV/℃ | |||
f | Frequency band | DC | ||||
TA | Operation temperature | -10~+70 | ℃ | |||
TS | Storage temperature | -25~+85 | ℃ | |||
RL | Load resistor | ≥10K | Ω | |||
Dimensions(mm) |
Instruction
1. The incorrect wiring connection may cause sensor damage. When the sensor is electrified, the measured current passes through the arrow direction of the sensor, the in-phase voltage can be measured at the output end.
2. The output amplitude of the sensor can be adjust appropriately according to the customers’ requirements.
3. Sensors with different rated input currents and output voltages can be customized according to user requirements.
Payment
1. We accept Western Union and T/T
2.30% deposit and 70% before shipping
3. No payment collection. We only can deliver goods after getting full payment.
Shipping
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country.